B-62694EN103
OPERATION
1 .FOR Series 16/l 8-B/C. Series 16i/l8i-A
NOTE
1
2
3
4
If the both NC parameters No.091 1 and No.0912 are equal
to 0, then the NC parameters are considered to be set as
follows.
No.091 1 = 32
(space)
No.0912 = 92 (“V)
If the both NC parameters No.091 3 and No.091 4 are equal
to 0, then the NC parameters are considered to be set as
follows.
No.091 3 = 64 (“@“)
No.091 4 = 58
(7
The NC parameters No.091 5 and No.0916 don’t have
default values.
In these three pairs,
the smaller pair is available
preferentially. That is to say, if the same value is set in
No.091 1, No.0913 and No.0915, the pair of No.091 1 and
No.091 2 is available.
5
In case of displaying the “DATA SERVER SETTING”
screen, the Data Server’s software exchanges the letters in
reverse and displays the setting data.
- 109-