B-62694ENl03 CONNECTION
2. FOR Series 16i/18i-A
22 . INSTALLATION
2.2. I Environmental Requirements
Keep the environmental requirements of CNC control unit in which
the Data Server board is installed.
Ambient At operation
5 to 45 degrees centigrade
Temperature No operation
-20 to 60 degrees centigrade
Temperature Maximum
20 degrees centigrade/hour
variance
Humidity Normally
10% to 75% (relative humidity)
For short terms
10% to 90% (relative humidity)
(within one month)
Vibration
At operation
0.5G or less (Note)
No operation
1 .OG or less (Note)
Atmosphere Mount in a sealed magnetic cabinet
CAUTION
Even if in the above environment, the data in the hard disk
may be destroyed for the mistake of operation or an
accident. Especially, the possibility of destruction is higher
to put off the power during accessing to the hard disk.
To provide against an emergency, please backup the data
in the hard disk periodically.
NOTE
About the vibration
The CNC control unit or in hard disk unit may vibrate at any
frequency. Please confirm not to vibrate after mounting the
CNC control unit in a magnetic cabinet.
-19-