B-62694ENl03
OPERATION
1 .FOR Series 16/l 8-B/C, Series 16i/l8i-A
NOTE
You must use “,” between O**** and Q Q Q Q.
You must specify O****
that is not registered in the HDD.
If you specify the registered O-number, an error occurs.
You can omit “@@I@ a”. In this case, Q 8 Q @ is equal to
0 ****. It is available in case that a file name in the Host
Computer is named by O-number.
And in this case, omit ‘I,” between O**** and 6 Q Q @ too.
You can use small letters at 8 Q @ Q.
Input a letter from A to Z after pressing the softkey
[ LOCK 1. This softkey [ LOCK ] is available till pressing this
softkey [ LOCK ] again.
In case that the file name stored in the Host Computer
includes a letter that can’t be inputted from the MDI keys,
you can specify the substitutional letter for only one letter.
Refer to the section “1.12 PARAMETERS”.
(4)Press the softkey [ EXEC 1.
(5)The blinking “GET” is displayed on the right and low of the
screen when getting a NC program.
[Example]
(1)
(2)
In case that you register “TEST.PRG” in the Host
Computer as the name of “00001” into the HDD, please
input “OOOOl,TEST.PRG”.
In case that you register “00002” in the Host Computer
as the name of “00002” into the HDD, please input
“00002,00002” or only “00002”.
NOTE
1 In case of transferring a large NC program, you are careful
because you can’t stop “GET” function.
2 If an error occurs in this function, “GET ERROR” is
displayed on the left and low of the screen.
Confirm the problem by referring to the section “1.11
ERROR MESSAGE”. About error messages, refer to the
section “APPENDIX A. TABLE OF ERROR MESSAGES”.
-75-