Connection between alpha i series amplifiers and Power Failure Backup Modul Additional Manual Page 1

Additional Manual
TECHNICAL REPORT (MANUAL) TMS01/034E
Date November 5, 2001
General Manager of
Servo Laboratory
Connection between αi series amplifiers and Power Failure Backup Module.
1. Distribute this report to the destinations marked with O:
O Your information
O GE Fanuc-N, GE Fanuc-E
Fanuc Robotics-NA, Fanuc Robotics-E
CINCINNATI MILACRON
O Machine tool builder
Sales agency
End user
2. Summary for Sales Documents
(Sales guide, Functional comparison list, etc.)
3. Notice
4. Attached Document
Drawing
No.
A-53866E-405 (Total 5 pages)
5. Registration of Order List data (In case of Order List)
Type of
Data
Lotus 123/Win, Oasys
Original Section of Issue
IDE Vice general
manager
Manager Chief
Person in
charge
FANUC

Contents Summary of Connection between alpha i series amplifiers and Power Failure Backup Modul Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) TMS01/034E Date November 5, 2001 General Manager of Servo Laboratory Connection between αi series amplifiers and Power Failure Backup Module. 1. Distribute this report to the destinations marked with O: O Your information O GE Fanuc-N, GE Fanuc-E Fanuc Robotics-NA, Fanuc Ro
  • Page 2Connection between αi series amplifiers and Power Failure Backup Module 1. Summary This document describes about the connection between αi series amplifiers and Power Failure Backup Module. The connection with αi series amplifiers is different at the following points from the connection with α serie
  • Page 32. Overall connection diagram (for Power Failure Backup Module A06B-6077-H002) * In case of Power Failure Backup Module A06B-6077-H001, Cable K64 and K66 is not needed. Connection between αi series amplifiers Subject and Power Failure Backup Module 01 21.Sept.’01 S.Hanyu Newly designed DWG.No A-5386
  • Page 43. Detailed connection of cables (1) Cable K75 Cable K75 is for supplying the control power (DC24V) to Power Failure Backup Module. SVM       CXA2A CX14 K75 24V (A1)  24V (B1) 0V (A2)  0V (B2) MIFA (A3)   BATL (B3) *ESP (A4) XMIFA (B4) Connector specification CXA2A C
  • Page 54. About the limit of the number of amplifiers connected to PSM In case that Power Failure Backup Module with control power backup function (A06B-6077- H002) is connected to αi series PSM, the number of amplifiers to which the control power 24V can be supplied from PSM is limited. The number of ampl
  • Page 65. The method of supplying the control power from the external power supply equipment. This section describes the method of supplying the control power 24V from the external power supply equipment in case that the number of SVMs connected to PSM exceeds the maximum number calculated in section 4. (1