B–63980EN/01
4. DESCRIPTION OF PARAMETERS
131
#7
7103
#6 #5 #4
IBH
#3
HIT
#2
HNT
#1 #0
[Data type] Bit
HNT The manual handle feed/incremental feed magnification is:
0 : Multiplied by 1.
1 : Multiplied by 10.
HIT The manual handle interruption magnification is:
0 : Multiplied by 1.
1 : Multiplied by 10.
IBH Manual handle feed for the β servo unit using an I/O link is:
0 : Disabled.
1 : Enabled.
7110 Number of manual pulse generators used
[Data type] Byte
[Valid data range] 1, 2, or 3
This parameter sets the number of manual pulse generators.
7113 Manual handle feed magnification m
[Data type] Word
[Unit of data] One time
[Valid data range] 1 to 127
This parameter sets the magnification when manual handle feed
movement selection signals MP1 and MP2 are set to 0 and 1.
7114 Manual handle feed magnification n
[Data type] Word
[Unit of data] One time
[Valid data range] 1 to 1000
This parameter sets the magnification when manual handle feed
movement selection signals MP1 and MP2 are set to 1.
Movement
selection signal
Movement
(Manual handle feed)
MP2 MP1
0 0 Least input increment 1
0 1 Least input increment 10
1 0 Least input increment m
1 1 Least input increment n