B–63980EN/01
4. DESCRIPTION OF PARAMETERS
133
#7
7200
#6
OP7
#5
OP6
#4
OP5
#3
OP4
#2
OP3
#1
OP2
#0
OP1
[Data type] Bit
OP1 Mode selection on software operator’s panel
0 : Not performed
1 : Performed
OP2 JOG feed axis select and JOG rapid traverse buttons on software
operator’s panel
0 : Not performed
1 : Performed
OP3 Manual pulse generator’s axis select and manual pulse generator’s
magnification switches on software operator’s panel
0 : Not performed
1 : Performed
OP4 JOG speed override and rapid traverse override switches on software
operator’s panel
0 : Not performed
1 : Performed
OP5 Optional block skip, single block, machine lock, and dry run switches on
software operator’s panel
0 : Not performed
1 : Performed
OP6 Protect key on software operator’s panel
0 : Not performed
1 : Performed
OP7 Feed hold on software operator’s panel
0 : Not performed
1 : Performed
#7
7201
#6 #5 #4 #3 #2 #1 #0
JPC
[Data type] Bit
JPC For the name of a general–purpose switch function on the software
operator’s panel, the use of full–size characters is:
0 : Not allowed.
1 : Allowed.
4.28