B–63980EN/01
4. DESCRIPTION OF PARAMETERS
141
8341 Program number subject to check termination
[Data type] Word
[Valid data range] 0 to 9999
This parameter sets the program number, including a sequence number,
subject to sequence number check termination. Parameter No.8342 is
used to set a sequence number subject to check termination.
NOTE
A program number can also be set on the setting screen. If
a program number is set on the setting screen, the value of
the parameter is changed accordingly.
8342 Sequence number subject to check termination
[Data type] 2–word
[Valid data range] 0 to 9999
This parameter sets the sequence number subject to sequence number
check termination.
If the block containing the sequence number set with this parameter is
executed while the program set with parameter No.8341 is being
executed, a single block stop occurs after the block is executed. At this
time, the setting is automatically set to –1.
NOTE
A sequence number can also be set by using the setting
screen. If a sequence number is set on the setting screen,
the value of the parameter is changed accordingly.
4.30
PARAMETERS OF
CHECK