B–63980EN/01
4. DESCRIPTION OF PARAMETERS
145
8760
Program number for data registration (data input/output function using the
I/O link)
[Data type] Word
[Valid data range] 0 to 9999
When the data input/output function using the I/O link is used, this
parameter sets the program numbers of the programs to be used for
registering data (parameters, macro variables, and diagnostic data) from
Power Mates.
For a Power Mate in group n, the following program numbers are used:
For parameters: Setting + n 10 + 0
For macro variables: Setting + n 10 + 1
For diagnostic data: Setting + n 10 + 2
Example: When 8000 is set
8000: Parameters of group 0 (I/O channel = 20)
8001: Macro variables of group 0 (I/O channel = 20)
8002: Diagnostic data of group 0 (I/O channel = 20)
8010: Parameters of group 1 (I/O channel = 21)
8011: Macro variables of group 1 (I/O channel = 21)
8012: Diagnostic data of group 1 (I/O channel = 21)
8020: Parameters of group 2 (I/O channel = 22)
8021: Macro variables of group 2 (I/O channel = 22)
8022: Diagnostic data of group 2 (I/O channel = 22)
8150: Parameters of group 15 (I/O channel = 35)
8151: Macro variables of group 15 (I/O channel = 35)
8152: Diagnostic data of group 15 (I/O channel = 35)
NOTE
When 0 is set, the input/output of parameters, macro
variables, and diagnostic data cannot be performed, but
program input/output processing is performed.
8790 Timing for executing an auxiliary macro
[Data type] Word
This parameter sets the timing for executing a macro executor auxiliary
macro while NC programs, offset data, and so forth are being read or
punched out.
When as many characters as the number specified with this parameter are
read or punched out, an auxiliary macro is executed once. When 0 is set in
this parameter, no auxiliary macro is executed during read or punch
processing.