B–63980EN/01
4. DESCRIPTION OF PARAMETERS
147
#7
8901
#6 #5 #4 #3 #2 #1 #0
FAN
[Data type] Bit
FAN A fan motor error is:
0 : Detected. (When the fan motor error is detected, an overheating alarm
occurs.)
1 : Not detected. (Use inhibited)
#7
8903
#6 #5 #4 #3 #2 #1 #0
PRM
[Data type] Bit
PRM A periodic maintenance expiration message is:
0 : Not displayed.
1 : Displayed.
8911 Ratio of the items on the periodic maintenance screen to the respective lives
[Data type] Byte
[Unit of data] 1%
[Valid data range] 0 to 100
On the periodic maintenance screen, if the remaining time of an item falls
to a value less than the percentage of the life specified in this parameter,
the remaining time is displayed in red as a warming.
8940 Title character code 1
8941 Title character code 2
:
8949 Title character code 10
[Data type] Byte
[Valid data range] See below.
When the CNC is turned on, up to ten characters specified in these
parameters are displayed on the screen showing the series and edition of
the CNC.
D The following characters can be used.
0 to 9, A to Z, – (minus sign), . (period), and space
D The character codes to be specified are listed in the character code list
in Appendix A.
D If any code other than those character codes that can be specified is
specified, a space is displayed.
4.33
PARAMETERS OF
MAINTENANCE