4. DESCRIPTION OF PARAMETERS
B–63980EN/01
152
#7 #6 #5 #4 #3 #2 #1 #0
16000 PEI NFI PFI RPF
[Data type] Bit
RPF When the RESET key is pressed or when external reset, reset and rewind,
or emergency stop is activated, the PF signal to start pressing is:
0: Set to 0.
1: Not set to 0.
PF is set to 0 only when the *PE signal to stop pressing is set to 0.
PFI The logic of the *PFIN signal to complete punching for single–cycle
pressing is:
0: The same as the logic described in the ”Connection Manual.”
1: The reverse of the logic described in the ”Connection Manual.”
NFI The logic of the *NFIN signal to complete punching for continuous
pressing is:
0: The same as the logic described in the “Connection Manual.”
1: The reverse of the logic described in the “Connection Manual.”
PEI The logic of the *PE signal to stop pressing is:
0: The same as the logic described in the “Connection Manual.”
1: The revese of the logic described in the “Connection Manual.”
#7 #6 #5 #4 #3 #2 #1 #0
16001 CPF MPF PMA PE2 PRC PFE MNP
[Data type] Bit
MNP If there remains a distance to be traveled when automatic operation is
halted, manual pressing or continuous manual pressing is:
0: Validated.
1: Invalidated.
PFE When the PF signal to start pressing is set to 1, the absolute value of
positional deviation for the X– and Y– axes:
0: Must be less than or equal to the value set in paramter 16010.
1: Need not be less than or equal to the value set in parameter 16010.
PRC When the machine lock signal, MLK, is set to 1, a program check is:
0: Not executed.
1: Executed.
The machine position data is updated although the actual position is not
changed. This setting is invalid for the machine lock signal of each axis.
PE2 To output the PF signal to start pressing, position check is executed at
intervals of:
0: 8 msec.
1: 2 msec.
PMA When the AFL signal to lock miscellaneous functions is set to 1, M code
signals for forming, repositioning, and nibbling are:
0: Not output to the machine.
1: Output to the machine.
4.35
PARAMETERS OF
THE PRESS
FUNCTION