B–63980EN/01
4. DESCRIPTION OF PARAMETERS
153
MPF In a block containing an M code, the PF signal to start pressing is:
0: Not set to 1.
1: Set to 1.
PF is set to 1 when movement along an axis terminates or when
completion of the miscellaneous function is returned.
CPF At the end of the 01 group containing the G01, G02, or G03 code, the PF
signal to start pressing is:
0: Not set to 1.
1: Set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
16002 EUP PF9 PWB SPR PFB PEM NIP AET
[Data type] Bit
AET The timer for issuing the EF signal to start external operation in advance
(parameter 16041) is:
0: Disabled.
1: Enabled.
NIP Upon the completion of punching, ITP shift is:
0: Performed (The delay between the completion of punching and the start
of axial movement is fixed to 19 ms.)
1: Not performed (The delay between the completion of punching and
the start of axial movement varies within a range of 11 to 19 ms.)
PEM MDI operation:
0: Does not start pressing.
1: Starts pressing.
PFB The PFB signal to start pressing is:
0: Enabled.
1: Disabled.
SPR The *SPR signal to halt automatic oparation B is:
0: Invalidated.
1: Validated.
PWB The PFWB signal to wait for the start of pressing B is:
0: Invalidated.
1: Validated.
PF9 The time interval between setting of the PFB signal to start pressing B to 0
and setting of the PF signal to start pressing to 0 is set to the value in:
0: Parameter 16037.
1: Parameter 16038.
EUP By executing the external operation function, the number of punching
cycles is:
0: Not aggregated.
1: Aggregated.
One is added when the PF signal to start pressing and the EF signal to
external operation are set to 1.