B–63980EN/01
4. DESCRIPTION OF PARAMETERS
155
NOTE
The parameter can only be set for the X, Y, and C axes.
16011 Duration for which the start of positioning is delayed
[Data type] Byte axis
[Unit of data] msec
[Valid data range] 0 to 248
For each axis, parameter 16011 sets the duration for which the start of
positioning is delayed.
NOTE
1 Only a multiple of 8 can be set for parameter 16011.
2 The parameter can only be set for the X, Y, and C axes.
Positioning
Time set in parameter 16011
Positioning in the
next block
16012 Time interval by which setting of PF to 1 precedes completion of positioning
[Data type] Byte axis
[Unit of data] msec
[Valid data range] 0 to 248
For each axis, parameter 16012 sets the time interval by which setting of
the PF signal to start pressing to 1 precedes completion of positioning.
(Function to advance setting of the PF signal)
NOTE
1 When parameter KLV (No. 16050, #7) is set to 1, the data
is invalidated. If it is invalidated, see the descriptions of
parameters 16013 to 16026.
2 The parameter can only be set for the X, Y, and C axes.