B–63980EN/01
4. DESCRIPTION OF PARAMETERS
159
Time interval by which setting PF to 0 follows setting *PE to 0 in single–cycle
pressing
16030
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16030 sets the time interval by which setting the PF signal to
start pressing to 0 follows setting the contact of the *PE signal to stop
pressing to 0 in single–cycle pressing.
Time interval between completion of positioning and the start of the next block
when PFL is set to 1
16031
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16031 sets the time interval between completion of positioning
and the start of the next block when are PFL signal to lock the start of
pressing is set to 1.
16032 Time interval by which setting of PF to 1 follows positioning in the forming mode
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16032 sets the time interval by which setting the PF signal to
start pressing to 1 follows positioning in the forming mode (except for
nibbling).
Time interval by which the start of the next bolck follows setting of *PFIN to 0 in
the forming mode
16033
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16033 sets the time interval by which the start of the next block
follows setting the contact of the *PFIN signal to complete punching for
single–cycle pressing to 0 in the forming mode.
Positioning
Time set in
parameter
16032
Next block
Time set in
parameter
16033
PF
*PFIN