4. DESCRIPTION OF PARAMETERS
B–63980EN/01
160
16034 Time interval by which setting PF to 1 follows first positioning in nibbling
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16034 sets the time interval by which setting the PF signal to
start pressing to 1 follows positioning at the first punch point in nibbling
(nibbling by G68, G69, and M code).
Time interval by which the start of the next block follows setting *NFIN to 0 at the
last positioning in nibbling
16035
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16035 sets the time interval by which the start of the next block
follows setting the contact of the *NFIN signal to complete punching for
continuous pressing to 0 at positioning at the last punch point in nibbling
(nibbling by G68, G69, and M code).
Minimum time interval by which setting of PF to 1 follows setting of *PFIN to 0 in
single–cycle pressing
16036
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16036 sets the minimum time interval by which setting the PF
signal to start pressingto 1 follows setting the contact of the *PFIN signal
to complete punching for single–cycle pressing to 0 in single–cycle
pressing. After the contact of *PFIN is set to 0, PF is set to 1 when the time
set here elapses. PF is not set to 1 even if positioning for the next block
completes and other conditions are satisfied before the time elapses.
Time interval by which setting PFB to 1 follows setting PF to 1 and settiug PF to
0 follows setting PFB to 0
16037
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 20
Parameter 16037 sets the time interval by which setting the PFB signal
to start pressing B to 1follows setting the PF signal to start pressing to 1
and setting PF to 0 follows setting PFB to 0.
NOTE
1 Only a multiple of 2 can be set for parameter 16037.
2 The parameter must be set to 0 when the PFB signal is not
used.