B–63980EN/01
4. DESCRIPTION OF PARAMETERS
161
PF
PFB
*PE
Time set in
parameter
16037
Time set in
parameter
16030
Time set in
parameter
16037
16038 Time interval by which setting PF to 0 follows setting PFB to 0
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 20
Parameter 16038 sets the time interval by which setting the PF signal to
start pressing to 0 follows setting the PFB signal to start pressing B to 0.
The data is validated when parameter PF9 (No. 16002, #6) is set to 1.
NOTE
Only a multiple of 2 can be set in parameter 16038.
PF
PFB
*PE
Time set in
parameter
16037
Time set in
parameter
16030
Time set in
parameter
16038
16039 Time interval by which setting PF to 0 follows setting *PE to 0 in nibbling
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 248
Parameter 16039 sets the time interval by which setting the PF signal to
start pressing to 0 follows setting the contact of the *PE signal to stop
pressing to 0 in nibbing.