B–63980EN/01
4. DESCRIPTION OF PARAMETERS
163
#7 #6 #5 #4 #3 #2 #1 #0
16050 KLV PCT CT2 KLC NCT PCF G0F
[Data type] Bit
G0F For a rapid traverse command (G00), the X–axis or Y–axis rapid traverse
feedrate is set to the value:
0: Specified in the parameter.
1: Specified by the F code.
The maximum feedrate of the F command is limited to the rapid traverse
feedrate in the parameter. KLV (No. 16050, #7) and LPG (No. 16051, #4)
are valid.
PCF The X–axis or Y–axis movement mode is selected for the following
blocks:
(1) Movement to each punch point with the pattern function (G26, G76,
G77, G78, etc.)
(2) Operation in automatic repositioning (G75)
(3) Movement to the first punch point with the nibbling function (G68,
G69, and M code)
0: Rapid traverse is executed.
1: For G00, rapid traverse is executed. For G01, G02, or G03, linear
interpolation cutting feed is executed.
NCT Constant control of positioning time is:
0: Always enabled.
1: Enabled only when the nibbling command is executed.
This parameter is valid when the PCT bit (bit 6 of parameter 16050) is set
to 1.
KLC When rapid traverse is executed in automatic operation, the function to
change the time constant and C–axis rapid traverse feedrate among three
levels according to the positioning angleis:
0: Invalidated.
1: Validated. See the descriptions of parameters 16140 to 16147.
CT2 In constant control of the positioning time, the times specified in
parameters 16095 to 16102 are:
0: Not changed.
1: Doubled.
PCT Constant control of positioning time is:
0: Invalidated.
1: Validated.
The parameter is validated when parameter KLV (No. 16050, #7) is set
to 1.
See the descriptions of parameters 16095 to 16102.
KLV When rapid traverse is executed in automatic operation, the function to
change the time constant and X–axis and Y–axis rapid traverse feedrates
among seven levels according to the positioning distance is:
0: Invalidated.
1: Validated. See the descriptions of data 16055 to 16094.
4.36
PARAMETERS FOR
THE SPEED AND
LOOP GAIN SWITCH