4. DESCRIPTION OF PARAMETERS
B–63980EN/01
164
#7 #6 #5 #4 #3 #2 #1 #0
16051 PGC LPG KLT
[Data type] Bit
KLT When rapid traverse is executed in automatic operation, the function to
change the servo loop gain of position control and time constant of T–axis
rapid traverse among three levels according to the indexed angle is:
0: Invalidated.
1: Validated.
See the descriptions of parameters 16117 to 16124.
LPG When rapid traverse is executed in automatic operation, the function to
change the servo loop gain of X–axis and Y–axis position control among
seven levels according to the positioning distance is:
0: Invalidated.
1: Validated.
The parameter is validated when parameter KLV (No. 16050, #7) is set
to 1.
See the descriptions of parameters 16103 to 16116.
PGC Servo loop gains of X–axis and Y–axis position control to be used in rapid
traverse and cutting feed:
0: Are the same.
1: Can be set separately. See the description of parameter 16160.
#7 #6 #5 #4 #3 #2 #1 #0
16052 TJG TCO NJC
[Data type] Bit
NJC The jog feedrate is:
0: Limited to the manual rapid traverse rate.
1: Not limited to the manual rapid traverse rate.
TCO For the T or C axis, a rapid traverse override is:
0: Validated.
ROV1 ROV2 T–axis or C–axis override
0 0 100%
1 0 100%
0 1 50%
1 1 50%
1: Invalidated. (The rapid traverse override is always 100%.)
TJG The jog override signals for the T–axis and C–axis (G233, #0 and #1) are:
0: Not used.
1: Used.
*JVT1 *JVT2 T–axis or C–axis override
1 1 25%
1 0 50%
0 1 75%
0 0 100%