4. DESCRIPTION OF PARAMETERS
B–63980EN/01
166
[Valid data range] 0 to 99999999
Each of the parameters set the positioning distance to use the function to
change the time constant and X–axis and Y–axis rapid traverse feedrate
among seven levels according to the positioning distance. (Identical
values are set for the X and Y axes.)
The data is validated when parameter KLV (No. 16050, #7) is set to 1.
NOTE
1 The values set here must satisfy the following relationship:
D1 < D2 < D3 < D4 < D5 < D6.
2 The values can be changed among seven levels or less.
When the values are to be changed among four levels, set
D4 to 99999999.
16067 X–axis rapid traverse feedrate of level 1
16068 X–axis rapid traverse feedrate of level 2
16069 X–axis rapid traverse feedrate of level 3
16070 X–axis rapid traverse feedrate of level 4
16071 X–axis rapid traverse feedrate of level 5
16072 X–axis rapid traverse feedrate of level 6
16073 X–axis rapid traverse feedrate of level 7
[Data type] Two–word
[Unit of data]
[Valid data range]
Increment system Units of data Valid data range
Millimeter machine 1 mm/min 30 to 240000
Inch machine 0.1 inch/min 30 to 96000
Each of the parameters set the X–axis rapid traverse feedrate for the
corresponding distance.