B–63980EN/01
4. DESCRIPTION OF PARAMETERS
169
16099 Y–axis positioning time of level 1 (Rapid traverse override of 100% or 75%)
16100 Y–axis positioning time of level 1 (Rapid traverse override of 50% or 25%)
16101 Y–axis positioning time of level 2 (Rapid traverse override of 100% or 75%)
16102 Y–axis positioning time of level 2 (Rapid traverse override of 50% or 25%)
[Data type] Byte
[Unit of data] msec
[Valid data range] 32 to 248
When constant control of the positioning time is applied, each of the
parameters set the X–axisor Y–axis positioning time for the positioning
distance of level one or two.
The parameters are validated when parameter KLV (No. 16050, #7) and
PCT (No. 16050, #6) are set to 1.
NOTE
When this function is used, parameters 16067, 16068,
16074, 16075, 16081, 16082, 16088, and 16089 are
invalidated. Constant control of the positioning time is
applied, irrespective of the positioning distance.
16103 X–axis servo loop gain of level 1
16104 X–axis servo loop gain of level 2
16105 X–axis servo loop gain of level 3
16106 X–axis servo loop gain of level 4
16107 X–axis servo loop gain of level 5
16108 X–axis servo loop gain of level 6
16109 X–axis servo loop gain of level 7
[Data type] Word
[Unit of data] 0.01 sec
–1
[Valid data range] 1 to 9999
Each of the parameters set the servo loop gain of X–axis position control
for the corresponding positioning distance.
See the descriptions of parameters 16055 to 16066.