B–63980EN/01
4. DESCRIPTION OF PARAMETERS
171
16122 T–axis servo loop gain of level 1
16123 T–axis servo loop gain of level 2
16124 T–axis servo loop gain of level 3
[Data type] Word
[Unit of data] 0.01 sec
–1
[Valid data range] 1 to 9999
Each of the parameters set the servo loop gain of T–axis position control
to use the function for changing the T–axis rapid traverse time constand
and servo loop gain of position control among three levels according to
the indexed angle.
See the descriptions of parameters 16117 and 16118.
16140 C–axis angle to level 1
16141 C–axis angle to level 2
[Data type] Two–word
[Unit of data] 0.01 deg (IS–A)/0.001 deg (IS–B)
[Valid data range] 0 to 99999999
Each of the paramters set the positioning angle to use the function for
changing the C–axis rapid traverse feedrate and time constant among
three levels according to the positioning angle.
The data is validated when parameter KLC (No. 16050, #4) is set to 1.
NOTE
The value of level 1 must be smaller than the value of level
2.
16142 C–axis rapid traverse feedrate of level 1
16143 C–axis rapid traverse feedrate of level 2
16144 C–axis rapid traverse feedrate of level 3
[Data type] Two–word
[Unit of data] 1 deg/min
[Valid data range] 30 to 240000
Each of the parameters set the C–axis rapid traverse feedrate to use the
function for changing the C–axis rapid traverse feedrate and rapid traverse
time constant among tree levels according to the positioning angle.
See the descriptions of parameters 16140 and 16141.