B–63980EN/01
4. DESCRIPTION OF PARAMETERS
173
#7 #6 #5 #4 #3 #2 #1 #0
16181 NPF NSP NPC NMG
[Data type] Bit
NMG When the M code for canceling the nibbling mode (No. 16184) is
specified, the G code in the 01 group is:
0: Not changed.
1: Changed to G00 (rapid traverse).
NPC The function to change maximum pitch in the nibbling mode between two
levels is:
0: Not used.
1: Used.
The function can be executed by the SNP signal for changing nibbling
between two levels or by the M code (No. 16185).
NSP When the *SP signal to halt automatic operation is set to 0 in nibbling,
automatic operation is:
0: Decelerated and halted immediately.
1: Halted after positioning for a nibbling pitch completes.
NPF In nibbling mode, a press sequence is:
0: Executed according to conventional signals, NBL and *NFIN.
1: Executed according to signals PF, *PFIN, and *PE.
When this parameter is set to 1, a press sequence is executed in the same
way as a sequence for single–cycle press.
16183 M code for setting the nibbling mode
16184 M code for canceling the nibbling mode
[Data type] Byte
[Valid data range] 1 to 255
Parameter 16183 sets the M code for setting the nibbling mode.
16185 M code for setting the nibbling mode in which nibbling is changed between two levels
[Data type] Byte
[Valid data range] 1 to 255
Parameter 16185 sets the M code for setting the nibbling mode in which
nibbling is changed between two levels.
The data is validated when parameter NPC (No. 16181, #1) is set to 1.
NOTE
The M code in parameter 16184 is used to cancel the
nibbling mode if set.
4.37
PARAMETERS FOR
THE NIBBLING
FUNCTION