B–63980EN/01
4. DESCRIPTION OF PARAMETERS
175
Maximum pitch of G00 command for changing nibbling between two levels
(in mm)
16192
Maximum pitch of G00 command for changing nibbling between two levels
(in inches)
16193
[Data type] Two–word
[Unit of data]
Increment system IS–A IS–B Units
Input in millmeters 0.01 0.001 mm
Input in inches 0.001 0.0001 inch
[Valid data range] 1 to 99999999
When nibbling by the M code (No. 16185) is executed or the SNP signal
for changing nibbling between two levels is set to 1 while the function for
changing nibbling between two levels is used,each of the parameters sets
the maximum nibbling pitch for the G00 command.
The data is validated when parameter NPC (No.16181, #1) is set to 1.
16194 Maximum distance traveled along C–axis in nibbling
[Data type] Two–word
[Unit of data] 0.01 deg (IS–A)/0.001 deg (IS–B)
[Valid data range] 1 to 99999999
The parameter sets the maximum distance traveled along the C–axis for
G68 and the nibbling mode.