4. DESCRIPTION OF PARAMETERS
B–63980EN/01
194
16533 Distance between the position detector of the workpiece holder and the punch
[Data type] Two-Word
[Unit of data]
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
[Valid data range] 0 to "99999999
The parameter sets the distance between the position detector of the
workpiece holder and punch.
The sign of the value set in the parameter corresponds to the direction the
machine travels along the X–axis, assuming the punch position as zero.
16534 Number of zones to be detected for automatic setting
[Data type] Byte
[Unit of data] Piece
[Valid data range] 0 to 4
This parameter specifies the number of zones to be detected for automatic
setting of a safety zone by an external signal.
NOTE
This parameter must be specified when automatic setting is
executed.
16535 Retraction position from the X–axis reference position for automatic setting
[Data type] Two-Word
[Unit of data]
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
[Valid data range] 0 to "99999999
This parameter specifies a clearance from the X–axis reference position
for automatic setting of a safety zone by means of an external signal.
NOTE
Specify a position that is sufficiently distant to allow the
speed at which the position of a workpiece holder is
detected to become stable.