B–63980EN/01
4. DESCRIPTION OF PARAMETERS
197
16600 Width for the second reference position on each axis
16601 Width for the third reference position on each axis
16602 Width for the fourth reference position on each axis
[Data type] Word
[Unit of data]
Increment system IS–A IS–B Units
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
[Valid data range] 0 to 65535
The parameters specify the width for the second, third, or fourth reference
position of the machine coordinate system. The second, third, or fourth
reference position signal is output within the range shown below:
Position specified in parameter 1241, 1242, or 1243
Negative direction
Positive direction
Second, third, or fourth reference position signal
Value specified in parame-
ter 16600, 16601, of 16602
Value specified in parame-
ter 16600, 16601, of 16602
NOTE
For a rotation axis, the specified reference position output
range must not include 0 of the machine coordinate system.
#7 #6 #5 #4 #3 #2 #1 #0
16747 SUV
[Data type] Bit
This parameter can be changed using the setting screen.
SUV In the reset state, the macros stored under U or V macro numbers are:
0: Deleted.
1: Not deleted.
This parameter is valid when the UVC bit (bit 0 of parameter 16200) is
set to 1.
4.42
ADDITIONAL
PARAMETERS FOR
DI/DO SIGNALS