B–63980EN/01
4. DESCRIPTION OF PARAMETERS
15
#7
NFD0121
#6 #5 #4 #3
ASI
#2 #1 #0
SB2
[Data type] Bit
These parameters are used when I/O CHANNEL is set to 2. The meanings
of the bits are the same as for parameter 0101.
0122 Number specified for the input/output device (when I/O CHANNEL is set to 2)
[Data type] Byte
Set the number specified for the input/output device used when I/O
CHANNEL is set to 2, with a value in Table 4.2 (a).
0123 Baud rate (when the I/O CHANNEL is set to 2)
[Data type] Byte
Set the baud rate of the input/output device used when I/O CHANNEL is
set to 2, with a value in Table 4.2 (b).
#7
0134
#6 #5 #4
NCD
#3 #2
SYN
#1
PRY
#0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
PRY Parity bit
0: Not used
1: Used
SYN Reset/alarm in protocol B
0: Not reported to the host
1: Reported to the host with SYN and NAK codes
NCD CD (signal quality detection) of the RS–232C interface
0: Checked
1: Not checked
4.2.4
Parameters of
Channel 2