4. DESCRIPTION OF PARAMETERS
B–63980EN/01
20
#7
0002
#6 #5 #4 #3 #2 #1 #0
RDG
[Data type] Bit
RDG Remote diagnosis is:
0: Not performed.
1: Performed.
If an RS–232C serial port is used to carry out remote diagnosis, connect
and set up the modem, cable, and the like, then set 1 in this parameter.
#7
0201
#6 #5 #4 #3 #2
NCR
#1
ASC
#0
SB2
[Data type] Bit
SB2 The number of stop bits is
0: 1.
1: 2.
To carry out remote diagnosis, set 0.
ASC The code to be used for data output is:
0: ISO code.
1: ASCII code.
To carry out remote diagnosis, set 1.
NCR EOB (end of block) is output as:
0: ”LF””CR””CR”.
1: Just as ”LF”.
To carry out remote diagnosis, set 1.
0203 Baud rate (for remote diagnosis)
[Data type] Byte
Set the baud rate of data input/output by remote diagnosis, with reference
to the tables given below.
When using an RS–232C serial port
Setting Baud rate (bps)
7
8
9
10
600
1200
2400
4800
9600
19200
Setting Baud rate (bps)
1
2
3
4
5
50
100
110
150
200
300
6
11
12
NOTE
The tables above indicate the baud rates of communication
between the CNC and modem. The actual communication
baud rate may be lowered, depending on the modem and
communication line.
4.4
PARAMETERS OF
REMOTE
DIAGNOSIS