4. DESCRIPTION OF PARAMETERS
B–63980EN/01
22
0221 Keyword 1 for remote diagnosis
0222 Keyword 2 for remote diagnosis
0223 Keyword 3 for remote diagnosis
[Data type] 2–word
[Valid range] 1 to 99999999
Set a keyword corresponding to a password of the remote diagnosis
function.
Keyword 1: Keyword for password 1 (parameter No. 211)
Keyword 2: Keyword for password 2 (parameter No. 212)
Keyword 3: Keyword for password 3 (parameter No. 213)
If any value other than 0 is specified as a password (parameters No. 211
to No. 213), the password can be changed only when the same value is
specified as the corresponding keyword.
NOTE
The keyword value is reset to 0 at power–up.
On the parameter screen, the keyword setting is not
displayed (blank display is provided).