B–63980EN/01
4. DESCRIPTION OF PARAMETERS
33
1020 Program axis name for each axis
[Data type] Byte axis
Set the program axis name for each controlled axis, using one of the values
listed in the following table:
Axis
name
Setting
Axis
name
Setting
Axis
name
Setting
Axis
name
Setting
X 88 U 85 A 65 T 84
Y 89 V 86 B 66
Z 90 W 87 C 67
NOTE
1 The same axis name cannot be assigned to more than one
axis.
2 When the addresses A, B, U, V, and W are used as the axis
name, refer to the parameters ABM and UVW (No. 16200 #6
and #7).
1022 Setting of each axis in the basic coordinate system
NOTE
When this parameter is set, power must be turned off before
operation is continued.
[Data type] Byte axis
To determine the following planes used for circular interpolation, cutter
compensation C (for the M series), tool nose radius compensation (for the
T series), etc., each control axis is set to one of the basic three axes X, Y,
and Z, or an axis parallel to the X, Y, or Z axis.
G17: Plane Xp–Yp
G18: Plane Zp–Xp
G19: Plane Yp–Zp
Only one axis can be set for each of the three basic axes X, Y, and Z, but
two or more parallel axes can be set.
Set value Meaning
0 Neither the basic three axes nor a parallel axis
1 X axis of the basic three axes
2 Y axis of the basic three axes
3 Z axis of the basic three axes
5 Axis parallel to the X axis
6 Axis parallel to the Y axis