4. DESCRIPTION OF PARAMETERS
B–63980EN/01
38
1280
First address of the signal group used by the external machine zero point shift
extension
[Data type] Word
[Valid data range] 0 to 65535
Set the first address of the signal group used by the external machine zero
point shift extension. If 100 is specified, R0100 to R0115 can be used.
Shift amount of external machine zero point shift extension for
the first axis (LOW)
Shift amount of external machine zero point shift extension for
the first axis (HIGH)
Shift amount of external machine zero point shift extension for
the second axis (LOW)
Shift amount of external machine zero point shift extension for
the second axis (HIGH)
Shift amount of external machine zero point shift extension for
the eighth axis (LOW)
Shift amount of external machine zero point shift extension for
the eighth axis (HIGH)
R0100
R0101
R0102
R0103
R0114
R0115
:
:
:
:
::
:
:
NOTE
1 This parameter is valid when bit 0 (EMC) of parameter No.
1203 is set to 1.
2 If the specified number is not present, the external machine
zero point shift extension is disabled.
3 A shift amount of the external machine zero point shift
extension can be written from the C executer or macro
executer.