4. DESCRIPTION OF PARAMETERS
B–63980EN/01
40
CAUTION
In the cases below, the automatic release function is
disabled. To release an alarm, a reset operation is required.
1 When a setting is made to issue an alarm before a stored
stroke limit is exceeded (bit 7 (BFA) of parameter No.
1300)
2 When an another overtravel alarm (such as stored stroke
check 2 and stored stroke check 3) is already issued
#7
1310
#6 #5 #4 #3 #2 #1 #0
OT2x
[Data type] Bit axis
OT2x Whether stored stroke check 2 is checked for each axis is set.
0: Stored stroke check 2 is not checked.
1: Stored stroke check 2 is checked.
1320 Coordinate value I of stored stroke check 1 in the positive direction on each axis
1321 Coordinate value I of stored stroke check 1 in the negative direction on each axis
[Data type] 2–word axis
[Unit of data]
Increment system IS–A IS–B Unit
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
Rotation axis 0.01 0.001 deg
[Valid data range] –99999999 to 99999999
The coordinate values of stored stroke check 1 in the positive and negative
directions are setfor each axis in the machine coordinate system. The
outside area of the two checks set in the parameters is inhibited.
(Xp,Yp,Zp)
Set the machine coordinates of the
boundaries in the positive direction
(Xp, Yp, and Zp) using parameter No.
1320, and those of the boundaries in
the negative direction (Xm, Ym, and
Zm) using parameter No. 1321. The
prohibited area thus becomes the
hatched area in the figure on the left.
(Xm,Ym,Zm)