B–63980EN/01
4. DESCRIPTION OF PARAMETERS
61
Controlled
axis
number
1
2
3
4
Program
axis name
No.1020
X
Y
Z
A
Servo axis
number
No.1023
1
2
3
4
Interface
type
Fast/Slow
F
F
S
S
CNC
2–axis
amplifier
1–axis
amplifier
X (Fast)
A (Slow)
Y (Fast)
Z (Slow)
1–axis
amplifier
IO1 A first I/O module supporting FSSB is:
0 : Not used.
1 Used.
IO2 A second I/O module supporting FSSB is:
0 : Not used.
1 Used.
PM1 The first separate detecter interface unit is:
0 : Not used.
1 : Used.
PM2 The second separate detecter interface unit is:
0 : Not used.
1 : Used.
NOTE
When automatic setting mode is selected for FSSB setting
(when the FMD parameter (bit 0 of parameter No.1902) is set
to 0), parameter No.1905 is automatically set when input is
performed with the FSSB setting screen. When manual
setting 2 mode is selected for FSSB setting (when the FMD
parameter (bit 0 of parameter No.1902) is set to 1),
parameter No.1905 must be set directly. When a separate
detecter interface unit is used, a connector number must be
set in the corresponding parameter (No.1936 or No.1937).