4. DESCRIPTION OF PARAMETERS
B–63980EN/01
70
#7
MHI3001
#6 #5 #4 #3 #2
RWM
#1 #0
[Data type] Bit
RWM RWD signal indicating that rewinding is in progress
0 : Output only when the tape reader is being rewound by the reset and
rewind signal RRW
1 : Output when the tape reader is being rewound or a program in
memory is being rewound by the reset and rewind signal RRW
MHI Exchange of strobe and completion signals for the M, S, T, and B codes
0 : Normal
1 : High–speed
#7
3002
#6 #5 #4
IOV
#3 #2 #1 #0
[Data type] Bit
IOV For the feedrate override signal and rapid traverse override signal:
0 : Negative logic is used.
1 : Positive logic is used.
#7
3003
#6
MVX
#5
DEC
#4 #3
DIT
#2
ITX
#1 #0
ITL
[Data type] Bit
ITL Interlock signal
0 : Enabled
1 : Disabled
ITX Interlock signals for each axis
0 : Enabled
1 : Disabled
DIT Interlock for each axis direction
0 : Enabled
1 : Disabled
DEC Deceleration signal (*DEC1 to *DEC4) for reference position return
0 : Deceleration is applied when the signal is 0.
1 : Deceleration is applied when the signal is 1.
MVX The axis–in–movement signal is set to 0 when:
0 : Distribution for the axis is completed. (The signal is set to 0 in
deceleration.)
1 : Deceleration of the axis is terminated, and the current position is in the
in–position.
If, however, a parameter specifies not to make in–position during
deceleration, the signal turns to “0” at the end of deceleration.
4.14
PARAMETERS OF
DI/DO