4. DESCRIPTION OF PARAMETERS
B–63980EN/01
72
3011 Acceptable width of M, S, T, and B function completion signal (FIN)
[Data type] Word
[Unit of data] 1 ms
[Valid data range] 16 to 32767
Set the minimum signal width of the valid M, S, T, and B function
completion signal (FIN).
M, S, T, B code
MF, SF, TF, BF
signal
FIN sigal
Ignored be-
cause shorter
than min.
signal width
Valid because
longer than min.
signal width
Fig.4.14 (b) Valid Width of the FIN (M,S, T, and B Function Completion)
Signal
NOTE
The time is counted in units of 8 ms. If the set value is not
a multiple of eight, it is raised to the next multiple of eight.
Example
When 30 is set, 32 ms is assumed.
3017 Output time of reset signal RST
[Data type] Byte
[Unit of data] 16 ms
[Valid data range] 0 to 255
To extend the output time of reset signal RST, the time to be added is
specified in this parameter.
RST signal output time = time veguired for reset + parameter 16 ms
3030 Allowable number of digits for the M code
3031 Allowable number of digits for the S code
3032 Allowable number of digits for the T code
[Data type] Byte
[Valid data range] 1 to 8
Set the allowable numbers of digits for the M, S, and T codes.
NOTE
Up to 5 digits can be specified in the S code