B–63980EN/01
4. DESCRIPTION OF PARAMETERS
73
#7
COR
#6 #5 #4 #3
FKY
#2
SKY
#1
CEM
#0
3100
[Data type] Bit
CEM On screens such as the operation history screen and help screen, keys on
the MDI panel are indicated:
0 : In English.
1 : With graphics qualifying for CE marking. (A character generator
supporting graphics qualifying for CE marking is required.)
SKY MDI key board use:
0 : Standard keys.
1 : Small keys.
NOTE
Set this parameter when using the 10.4” LCD (with ten soft
keys). After this parameter has been set, the power must be
turned off then back on for the setting to become effective.
FKY MDI keyboard
0 : Small type keys are used.
1 : Standard keys are used.
NOTE
Set this parameter when using the 7.2”/8.4” LCD (with seven
soft keys). After this parameter has been set, the power must
be turned off then back on for the setting to become
effective.
COR Display
0 : Monochrome display
1 : Color display
NOTE
When using the 8.4” LCD, set this bit to 1.
#7
3101
#6 #5 #4
BGD
#3 #2 #1
KBF
#0
[Data type] Bit
KBF When the screen or mode is changed, the contents of the key–in buffer are:
0 : Cleared.
1 : Not cleared.
4.15
PARAMETERS OF
DISPLAY AND EDIT