4. DESCRIPTION OF PARAMETERS
B–63980EN/01
76
#7
OHS
3106
#6 #5 #4
OPH
#3 #2 #1
GPL
#0
[Data type] Bit
GPL On the program list screen, the list–by–group function is:
0 : Disabled
1 : Enabled
OPH The operation history screen is:
0 : Not displayed.
1 : Displayed.
OHS Operation history sampling is:
0 : Performed.
1 : Not performed.
#7
MDL3107
#6 #5 #4
SOR
#3 #2
DNC
#1 #0
[Data type] Bit
DNC Upon reset, the program display for DNC operation is:
0 : Not cleared
1 : Cleared
SOR Display of the program directory
0 : Programs are listed in the order of registration.
1 : Programs are listed in the order of program number.
MDL Display of the modal state on the program display screen
0 : Not displayed
1 : Displayed (only in the MDI mode)
#7
JSP
3108
#6 #5 #4
WCI
#3
PCT
#2 #1 #0
[Data type] Bit
PCT On the 7–pieces type soft key display program check screen and
12–pieces type soft key display position screen, T code displayed
0 : is a T code specified in a program (T).
1 : is a T code specified by the PMC (HD. T/NX. T)
WCI On the workpiece coordinate system screen, a counter input is:
0 : Disabled.
1 : Enabled.
JSP On the current position display screen and program check screen, jog feed is:
0 : Not displayed.
1 : Displayed.