B–63980EN/01
4. DESCRIPTION OF PARAMETERS
77
NOTE
In manual operation mode, the jog feedrate is displayed. In
automatic operation mode, the dry run feedrate is displayed.
In each case, the feedrate to which a manual feedrate
override has been applied is displayed.
JOG F 8000 PART COUNT 15
RUN TIME 1H17M CYCLE TIME 1H15S
ACT.F 1000 MM/M
MEM STRT MTN *** 12:34:59
[ ] [ ] [ ] [ ] [ ]
Jog
feedrate
#7
3109
#6 #5
RHD
#4 #3 #2
IKY
#1 #0
[Data type] Bit
IKY On the tool offset screen, soft key [INPUT] is:
0 : Displayed.
1 : Not displayed.
RHD When a manual handle interrupt is generated, the relative position display is:
0 : Not updated.
1 : Updated.
NOTE
This parameter is enabled when the INH parameter (bit 2 of
parameter No.7100) is 1.
#7
3110
#6 #5 #4
OPC
#3 #2
AHC
#1 #0
[Data type] Bit
AHC With a soft key, the alarm history:
0: Can be cleared.
1: Cannot be cleared.
OPC The [ERASE] soft key on the operation history screen is:
0 : Disabled.
1 : Enabled.
#7
NPA3111
#6 #5
OPM
#4 #3 #2 #1 #0
SVS
[Data type] Bit
SVS Servo tuning screen
0 : Not displayed
1 : Displayed
OPM Operating monitor
0 : Not displayed
1 : Displayed