4. DESCRIPTION OF PARAMETERS
B–63980EN/01
80
#7
3115
#6
D10x
#5 #4 #3
NDFx
#2 #1
NDAx
#0
NDPx
[Data type] Bit axis
NDPx Display of the current position for each axis
0 : The current position is displayed.
1 : The current position is not displayed.
NDAx Position display using absolute coordinates and relative coordinates is:
0 : Performed.
1 : Not performed. (Machine coordinates are displayed.)
NDFx To the actual speed display, axis movement data is:
0 : Added.
1 : Not added.
NOTE
Even if the PCF parameter (bit 1 of parameter No.3105) is
set to 0, so as to add PMC controlled axis movement data
to the actual speed display, the movement data for a PMC
controlled axis for which NDFx is set to 1 is not added to the
actual speed display.
#7
MDC3116
#6
T8D
#5
COA
#4
FOV
#3 #2
PWR
#1 #0
[Data type] Bit
PWR Alarm No.100 (parameter enable) :
0 : Clear by
CAN
+
RESET
key
1 : Clear by
RESET
key
FOV In the field of specified feedrate F on the program check screen,
0 : The specified feedrate is displayed.
1 : (Specified feedrate) x (override) is displayed.
COA While an external alarm state is present or while an external message is
being displayed, automatic screen erasure is:
0 : Performed.
1 : Not performed.
T8D T codes that are always displayed are displayed with:
0 : Four digits.
1 : Eight digits.
This parameter expands the T code display to eight digits for the
continuous S or T display (bit 2 (DPS) of parameter No. 3105 is set to 1).
MDC Maintenance information by operating soft key :
0 : All clear disable.
1 : All clear enable.