4. DESCRIPTION OF PARAMETERS
B–63980EN/01
84
3197 Detection time of continuous pressing on touch panel
[Data type] Byte
[Unit of data] s
[Valid data range] 0 to 255
This parameter is valid if bit 2 (TRA) of parameter No. 3192 is set to 1.
Set a period of continuous pressing on the touch panel which causes
P/S5305 alarm to be raised. If 0 is set, a period of 20 s is assumed.
#7
MIP3201
#6
NPE
#5
N99
#4 #3
PUO
#2
REP
#1
RAL
#0
[Data type] Bit
RAL When programs are registered through the reader/puncher interface
0 : All programs are registered.
1 : Only one program is registered.
REP Action in response to an attempt to register a program whose number is
the same as that of an existing program
0 : An alarm is generated.
1 : The existing program is deleted, then the new program is registered.
Note that if the existing program is protected from being edited, it is
not deleted, and an alarm is generated.
PUO When address O of a program number is output in ISO code:
0 : “:” is output.
1 : “O” is output.
N99 With an M99 block, when bit 6 (NPE) of parameter No.3201 = 0, program
registration is assumed to be:
0 : Completed
1 : Not completed
NPE With an M02, M30, or M99 block, program registration is assumed to be:
0 : Completed
1 : Not completed
MIP Program registration by external start signal (MINP) :
0 : Not performed.
1 : Performed.
#7
3202
#6
PSR
#5
CPD
#4
NE9
#3
OSR
#2
CND
#1
OLV
#0
NE8
[Data type] Bit
NE8 Editing of subprograms with program numbers 8000 to 8999
0 : Not inhibited
1 : Inhibited
The following edit operations are disabled:
(1) Program deletion (Even when deletion of all programs is specified,
programs with program numbers 8000 to 8999 are not deleted.)
(2) Program output (Even when outputting all programs is specified,
programs with program numbers 8000 to 8999 are not output.)
(3) Program number search