B–63980EN/01
4. DESCRIPTION OF PARAMETERS
87
#7
MCK3205
#6 #5 #4
OSC
#3
PNS
#2 #1 #0
COL
[Data type] Bit
COL When a program is displayed or output, any colons (:) in the comments of
the program are:
0 : Converted to letter O
1 : Displayed or output as is colon (:)
PNS On the program screen, a search by a cursor key is:
0 : Performed.
1 : Not performed.
OSC On the offset screen, offset value erasure by a soft key is:
0 : Enabled.
1 : Disabled.
MCK The system tape memory check function is:
0 : Not used.
1 : Used. (This setting is inhibited.)
#7
3206
#6 #5 #4
PHS
#3 #2 #1
MIF
#0
[Data type] Bit
MIF Editing of the maintenance information screen is:
0 : Not prohibited.
1 : Prohibited.
PHS The selection of an operation history signal and parameters (No. 12801 to
No. 12900) are:
0 : Not linked.
1 : Linked.
#7
3207
#6 #5 #4 #3 #2 #1 #0
OM4
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit
OM4 A message displayed on the external operator message screen can have:
0 : Up to 256 characters, and just a single message can be displayed.
1 : Up to 64 characters, and up to four messages can be displayed.