B–63670EN/01
4. DESCRIPTION OF PARAMETERS
29
15206 Time constant of power sensor input filter
[Data type] Word
[Unit of data] Millisecond
[Valid data range] 8 to 32767
The time constant is used when the primary delay filter is applied to the
laser power monitor value input from the power sensor.
15207 Upper limit on power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
When the specified power value exceeds this setting after power
calibration and power feedback addition, the actual power is clamped to
this setting.
15208 Laser power feedback gain
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
Specify a laser power feedback gain.
15209 Power feedback amount clamp
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
The power specification is clamped to this setting in power feedback.
15210 Maximum output power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
When an output power higher than this setting is specified, the actual
power is clamped to this setting.
15211 Minimum output power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
When an output power lower than this setting is specified, the actual
power is clamped to this setting.