B–63670EN/01
4. DESCRIPTION OF PARAMETERS
77
15770 Feedrate of step feed or return
[Data type] Two–word
[Unit of data, valid data range]
Valid data range
Increment system Unit of data
IS–A, IS–B IS–C
Millimeter machine system 1 mm/min 0 to 240000 0 to 100000
Inch machine system 0.1 inch/min 0 to 96000 0 to 48000
Specify the feedrate to be used when the step feed or return function is
specified from the teaching box.
15771 Wait time after which C command processing will be executed
[Data type] Word
[Unit of data] 16 msec
[Valid data range] 0 to 10
Specify the wait time after which the teaching box C command will be
executed.
#7
15775
#6 #5 #4 #3
TIE
#2
MCL
#1
MEN
#0
NST
[Data type] Bit
NST For the step feed and return functions:
0 : Settings of bit 1 (MEN), bit 2 (MCL), and bit 3 (TIE) of parameter No.
15775 are enabled.
1 : Settings of bit 1 (MEN), bit 2 (MCL), and bit 3 (TIE) of parameter No.
15775 are disabled.
MEN In the step feed and return functions, M codes are:
0 : Not output.
1 : Output.
MCL In the step feed and return functions, macro and subprogram calls are:
0 : Disabled.
1 : Enabled.
TIE In the step feed and return functions, spatial corner rounding is:
0 : Enabled.
1 : Disabled.
4.33
STEP FEED
FUNCTION AND