Contents Summary of FANUC Series 16i /18i /21i Additional Manual
Page 1FANUC Series 16i /18i /21i –MB/TB Feed-forward / FAD function enable / disable signal Specification - Contents - 1 GENERAL.........................................................................................................................................................2 2 SPECIFICATION........
Page 21. General This is the function that enables feed-forward function or FAD function (fine acceleration / deceleration function) by using PMC signals. 2. Specification When the signal FDFCGx is set to 1, feed-forward or FAD function can be controlled by the signal FDFONx. In case FDFCGx
Page 33. Signals Feed-forward / FAD control change signal FDFCG1~8 [Classification] Input signal [Function] Change feed-forward / FAD control from CNC or PMC for each axis [Operation] When FDFCGx is set to 1, feed-forward or FAD function is controlled by the PMC signal FDFONx. When FDFCGx is s
Page 44. References - FANUC AC SERVO MOTER alpha i series PARAMETER MANUAL (B-65270EN) - FANUC AC SPINDLE MOTER alpha i series PARAMETER MANUAL (B-65280EN) FANUC Series 16i /18i /21 i – MB/TB Feed-forward / FAD function enable/disable signal Title Specification Draw A-79902E No. Edit Date Design Descripti