B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 131 -
3013
X address to which the deceleration signal for reference position return is
assigned
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 727
Set an address to which the deceleration signal (*DECn) for reference
position return for each axis is to be assigned.
NOTE
This parameter is valid when bit 2 (XSG) of
parameter No. 3008 is set to 1.
Depending on the option configuration of the I/O
Link, the actually usable X addresses are:
X0 to X127, X200 to X327, X400 to X527, X600 to
X727
3014
Bit position of an X address to which the deceleration signal for reference
position return is assigned
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 0 to 7
Set a bit position to which the deceleration signal for reference
position return (*DECn) for each axis is to be assigned.
NOTE
This parameter is valid when bit 2 (XSG) of
parameter No. 3008 is set to 1.
3017 Output time of reset signal RST
[Input type] Parameter input
[Data type] Word path
[Unit of data] 16msec
[Valid data range] 0 to 255
When the output time of the reset signal RST is to be extended, set an
extended time.
(RST signal output time) =
(Time required for reset processing) + (Parameter setting) × 16 msec