B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 145 -
3134
Data display order of each axis on the workpiece coordinate system setting
screen and workpiece coordinate system shift amount setting screen
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 0 to Number of controlled axes
Set the data display order of each axis on the workpiece coordinate
system setting screen (M series/T series) and workpiece coordinate
system shift amount setting screen (T series).
No data is displayed for an axis with 0 set in this parameter.
3135 Number of decimal places in actual feedrate display
[Input type] Setting input
[Data type] Byte path
[Valid data range] 0 to 3
Set the number of decimal places in actual feedrate display.
In the case of inch input, the number of decimal places is a set value
plus 2.
Setting value
0 : Metric input Displayed without a decimal point
Inch input Displayed using the second decimal place
1 : Metric input Displayed using the first decimal place
Inch input Displayed using the third decimal place
2 : Metric input Displayed using the second decimal place
Inch input Displayed using the fourth decimal place
3 : Metric input Displayed using the third decimal place
Inch input Displayed using the fifth decimal place
3141 Path name (1st character)
3142 Path name (2nd character)
3143 Path name (3rd character)
3144 Path name (4th character)
3145 Path name (5th character)
3146 Path name (6th character)
3147 Path name (7th character)
[Input type] Parameter input
[Data type] Byte path
[Valid data range] See the character-code correspondence table.
Specify a path name with codes.