4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 270 -
5214 Setting of an allowable rigid tapping synchronization error range
[Input type] Parameter input
[Data type] 2-word spindle
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
This parameter sets an allowable synchronization error range in rigid
tapping.
If a synchronous error range exceeding the setting of this parameter is
detected, the alarm (SP0741) is issued. When 0 is set in this parameter,
no synchronization error check is made.
5221 Number of gear teeth on the spindle side in rigid tapping (first gear)
5222 Number of gear teeth on the spindle side in rigid tapping (second gear)
5223 Number of gear teeth on the spindle side in rigid tapping (third gear)
Number of gear teeth on the spindle side in rigid tapping (fourth gear)
5224
[Input type] Parameter input
[Data type] Word spindle
[Valid data range] 1 to 32767
Each of these parameters is used to set the number of gear teeth on the
spindle side for each gear in rigid tapping.
NOTE
When a position coder is attached to the spindle, set
the same value for all of parameters No.5221
through No.5224.