4.27 PARAMETERS OF INDEX TABLE INDEXING
#7 #6 #5 #4 #3 #2 #1 #0
5500 IDX SIM G90 INC ABS REL DDP
[Input type] Parameter input
[Data type] Bit path
# 0 DDP As the method for inputting a decimal point in a command for the
index table indexing axis:
0: The conventional method is used.
1: The pocket calculator method is used.
# 1 REL The position display of the index table indexing axis in the relative
coordinate system is:
0: Not rounded by one rotation.
1: Rounded by one rotation.
# 2 ABS The position display of the index table indexing axis in the absolute
coordinate system is:
0: Not rounded by one rotation.
1: Rounded by one rotation.
# 3 INC When the M code that specifies rotation in the negative direction
(parameter No. 5511) is not set, rotation in the G90 mode is:
0: Not set to the shorter way around the circumference.
1: Set to the shorter way around the circumference.
# 4 G90 A command for the index table indexing axis is:
0: Assumed to be an absolute or incremental command according to
the mode.
1: Always assumed to be an absolute command.
# 6 SIM When the same block includes a command for the index table
indexing axis and a command for another controlled axis:
0: The alarm (PS1564) is issued.
1: The commands are executed. (In a block other than G00, G28,
or G30, however, the alarm (PS1546) is issued.)
# 7 IDX Operation sequence of the index table indexing axis:
0: Type A
1: Type B