B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 323 -
6221 Torque limit dead zone time for a torque limit skip command
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] msec
[Valid data range] 0 to 65535
The torque limit skip arrival signal is ignored for a set period of time.
If G31P98 is specified, skip operation is not performed for a set period
of time after the torque limit skip arrival signal is set to 1.
If G31P99 is specified, skip operation is not performed for a set period
of time after the torque limit skip arrival signal is set to 1.
However, if a skip signal is input, skip operation is performed,
regardless of the period of time set in this parameter.
#7 #6 #5 #4 #3 #2 #1 #0
6224 1A8 1A7 1A6 1A5 1A4 1A3 1A2 1A1
[Input type] Parameter input
[Data type] Bit path
1A1 to 1A8 Specify which high-speed measurement position arrival signal is to be
enabled for each AE1 signal of G37 (automatic tool length
measurement (M series) or automatic tool compensation (T series)).
Parameter Corresponding high-speed measurement position
arrival signal
1A1 HAE1
1A2 HAE2
1A3 HAE3
1A4 HAE4
1A5 HAE5
1A6 HAE6
1A7 HAE7
1A8 HAE8
0: The corresponding high-speed measurement position arrival
signal is disabled.
1: The corresponding high-speed measurement position arrival
signal is enabled.