4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 346 -
4.43 PARAMETERS OF REFERENCE POSITION WITH
MECHANICAL STOPPER
7181
First withdrawal distance in reference position setting with mechanical
stopper
7182
Second withdrawal distance in butt-type reference position setting with
mechanical stopper
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets a distance an axis in each cycle operation, along
which withdrawal is performed after the mechanical stopper is hit
(distance from the mechanical stopper to the withdrawal point).
NOTE
Set the same direction as that set in bit 5 (ZMIx) of
parameter No. 1006. Cycle operation cannot be
started if the opposite direction is set.
7183 First butting feedrate in reference position setting with mechanical stopper
7184
Second butting feedrate in reference position setting with mechanical
stopper
7185
Withdrawal feedrate (common to the first and second butting operations) in
reference position setting with mechanical stopper
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
This parameter sets a feedrate used to butt against the stopper along an
axis in each cycle.