4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 394 -
# 2 PKUx In the parking state,
0: The absolute, relative, and machine coordinates are not updated.
1: The absolute and relative coordinates are updated. The machine
coordinates are not updated.
NOTE
1 With an axis for which polar coordinate interpolation
is specified, set this parameter to 1. If this
parameter is set to 0, a coordinate shift can occur
when a single block stop or feed hold is performed in
the polar coordinate interpolation mode.
2 With an axis that is set to function as a synchronous
master axis and synchronous slave axis at the same
time (with bit 1 (SYWx) of parameter No. 8167), set
this parameter to 1.
3 With an axis specified in the three-dimensional
coordinate conversion mode, set this parameter to 1.
If this parameter is set to 0, the alarm (PS0367) is
issued.
# 3 OMRx Superimposed mirror-image control is:
0: Not applied. (The superimposed pulse is simply added.)
1: Applied. (The inverted superimposed pulse is added.)
# 4 MPMx When composite control is started, the workpiece coordinate system
is:
0: Not set automatically.
1: Set automatically.
NOTE
When the workpiece coordinate system is
automatically set at the start of composite control, it
is calculated from the following: Current machine
coordinates and the workpiece coordinates at the
reference point of each axis (parameter No.8184).
# 5 MPSx When composite control is terminated, the workpiece coordinate
system is:
0: Not set automatically.
1: Set automatically.
NOTE
When the workpiece coordinate system is
automatically set at the end of composite control, it
is calculated from the following: Current machine
coordinates and the workpiece coordinates at the
reference point of each axis under composite control
(parameter No.1250)