B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 433 -
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 0 to 99999999
This parameter sets the program numbers of programs to be used for
inputting and outputting slave data (parameters) when the Power Mate
CNC manager function is used.
For a slave specified with I/O LINK channel m and group n, the
following program number is used:
Setting + (m - 1) × 100 + n × 10
8781 DRAM size used for the C language executor
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Unit of data] 64KByte
[Valid data range] 12 to 96
This parameter sets the size of DRAM used for the C language
executor. Specify a value greater than or equal to 768K bytes in
64K-byte units. When a value not within the valid data range is set,
the specification of 0 is assumed.
When 0 is set, the C language executor is not started.
NOTE
The actually usable size depends on the RAM
capacity and option configuration.